XNX Xnx Honeywell Analytics 4
The XNX XNX Universal Gas Transmitter from Honeywell Analytics is a versatile and reliable instrument for detecting a wide range of gasses, including toxic, oxygen, and combustible gasses. It offers modular inputs and outputs, easy installation, user-friendly operation, and self-diagnostic tools. It’s highly customizable and finds use in various industries and applications, from oil and gas to fire detection and HVAC systems.
In this article, we will take a closer look at the XNX Universal Gas Transmitter, including its features, benefits, and applications. We will also discuss how to select the right XNX transmitter for your needs.
Get in touchGas Detection
Sensor Technology
Alarm Systems
Real-time Monitoring
User-friendly Interface
Compliance and Standards
Honeywell Analytics
Xnx Xnx Honeywell Analytics 4, a division of Honeywell, specializes in providing gas detection and monitoring solutions across various industries. Their offerings include gas detectors, flame detectors, software, and services used in oil and gas, petrochemical, chemical, pharmaceutical, food and beverage, and manufacturing applications. They prioritize innovation to ensure the safety of people and property from hazardous gasses.
A Brief History Honeywell Analytics: Founded in 1959 by Joshua Seiger, began as a gas detection manufacturer for the industrial boating industry and gained recognition by developing a gas detection system for Shell’s operations. In 1980, it entered the flammable gas market and was later acquired by Zellweger Analytics, which facilitated further expansion and the development of the company’s first carbon monoxide detector. In 2005, Honeywell Analytics was acquired by Honeywell International, cementing its status as a leading provider of reliable and effective safety solutions, particularly in the field of gas detection and protection.
Learn moreTop Quality
Qualified personnel
Work to fit your timetable
Honeywell XNX Universal Transmitter Features and Benefits
xnx xnx transmitter gas detection system designed to identify flammable gasses and provides the following key features:
- Flammable gas detection 0 to 100% LFL/LEL: This means the system can detect the presence of flammable gasses in a range from 0% to 100% of the Lower Flammable Limit (LFL) or Lower Explosive Limit (LEL). This wide range ensures it can detect even small traces or high concentrations of flammable gasses, offering comprehensive coverage.
- Flexible operation options: The system provides various ways to operate or configure it. This flexibility allows users to adapt the system to their specific needs or the conditions of the environment where it’s installed. For instance, it might include adjustable sensitivity settings, alarm thresholds, or output options to integrate with other safety systems.
- Minimal training required: Using this gas detection system does not demand extensive training. It is designed to be user-friendly, allowing operators to understand and use it with ease. This reduces the time and resources needed for training, making it accessible to a broader range of users.
Specifications Xnx Transmitter Honeywell
- Material: LM25 aluminum, painted (SS316 painted optional): The material used is LM25 aluminum, which is typically used in manufacturing. It is painted to protect it from various environmental factors. Optionally, you can choose SS316, which is a type of stainless steel, also painted for added protection.
- Temperature: -40° to +65°C / -40° to +150°F (sensor dependent): The material can withstand temperatures ranging from -40 degrees Celsius to +65 degrees Celsius (-40 to +150 degrees Fahrenheit). The specific temperature range may vary depending on the sensors used in conjunction with this material.
- Humidity: 20 to 90% RH (non-condensing): The material can tolerate humidity levels between 20% and 90% relative humidity without forming condensation (water droplets). Beyond this range, it may be affected or damaged.
About XNX Xnx Transmitter Honeywell 40
The XNX Universal Transmitter, a cutting-edge gas detection system meticulously engineered for use in hazardous environments. This versatile system employs a range of sensor technologies to effectively identify toxic gasses, flammable gasses, and oxygen depletion gas hazards. Each sensor technology is accompanied by a dedicated personality board for optimized performance.
Catalytic bead: The catalytic bead technology, with its mV personality board, is ideal for detecting combustible gasses.
Electrochemical (EC): The electrochemical technology, paired with the electrochemical board, excels at measuring toxic gasses with the help of Reflex cell fault diagnosis.
Infrared (IR): The infrared technology, supported by the IR board, efficiently absorbs gasses within the infrared spectrum.
Additionally, xnx transmitter honeywell offers optional communication boards, including relay, Modbus, and HART, ensuring seamless data exchange and system control. With its 4-20mA output refreshed at a configurable rate, the XNX transmitter provides real-time data proportional to gas concentration and can handle alarm conditions effectively.
The XNX offers over 200 different setups to meet safety standards for hazardous environments in industries like oil, chemicals, wastewater, and more. It’s designed to be intrinsically safe and explosion-proof, ensuring it complies with Class 1 and Class 2 requirements for both upstream and downstream operations.
Moreover, it is certified for safe operation in hazardous locations, making it a dependable choice for gas detection needs. Its versatility and reliability are further underscored by certifications such as UL, CSA, ATEX, and INMETRO, demonstrating compliance with stringent safety standards. The XNX Universal Transmitter is your go-to solution for dependable gas detection in challenging environments.
Advantages of Xnx Universal Transmitter Honeywell
High Performance
Xnx honeywell analytics 4x5x5 excels in detecting flammable gasses from 0 to 100% LFL/LEL, and its Point IR technology with heated optics ensures it is resistant to contamination and hidden faults. Open-path IR detection for flammable gasses is also supported. The electrochemical cell provides precise toxic gas detection in parts per million (ppm), and the IR cell monitors both CO2 and combustible gasses reliably, even in harsh and explosive environments.
Flexible Operation
With three versions accommodating various gas detection methods, xnx transmitter honeywell x is versatile. The Multi-Purpose Detector (MPD) supports multiple sensor types and can be serviced in the field. It uses the standard 4-20mA with HART communication and offers Enhanced Device Description Language (EDDL) software. Multiple communication options, including up to three relays, MODBUS, and FOUNDATION Fieldbus, make it adaptable to different setups. There is also an option for a local IS port for handheld HART configuration.
Easy to Use
The XNX features a user-friendly interface with a large, backlit LCD display, which uses visual icons and colored buttons to present gas and sensor readings clearly. It supports eight different languages for accessibility. Self-test and fault indication features enhance reliability, and it’s designed for easy, non-intrusive one-person operation. Quick calibration with auto-inhibit further simplifies maintenance.
Easy to Install
Its 3 or 4 wire operation and multiple configurations (source, sink, or isolated) make installation straightforward. Plug-in sensors and replaceable cells reduce downtime. The NEMA 4X IP66 rating ensures it’s suitable for rugged indoor and outdoor use, and five conduit entries simplify the installation process.
Cost Effective
The XNX is cost-effective in various ways. It requires minimal training, and one person can handle its operation and maintenance. Plug-in sensor replacement minimizes downtime, and all necessary accessories are included, saving on additional costs.
Global Approvals
- European, US and Canadian
- Compliant with ATEX, UL and CSA standards
- ATEX, UL and CSA performance approval
- IEC61508 SIL 2
Bringing Together the Best Solutions in Gas Detection
Xnx xnx honeywell analytics integrate and offer the top-notch technologies and approaches to create a comprehensive and reliable system for detecting and monitoring gasses:
Electrochemical
- Proven electrochemical sensing technology
- Surecell™ electrochemical cells are ideal for hot and humid environments
- Long life sensing cells (typical >2 years)
- Patented ‘Reflex’ sensing element verification diagnostics
- Sensor recognition software auto configures transmitter
- Plug and play factory configured sensors
- Intrinsically safe sensor connection permits hot swap, reducing down time
Catalytic Bead
- Supports Honeywell Analytics 705, 705HT, Sensepoint, Sensepoint HT and MPD sensors
- Fast response to wide range of hydrocarbons and flammables
Infrared (Open Path IR, Point IR, IR Cell)
- Supports Honeywell Analytics Searchline Excel, Searchpoint Optima Plus
- Failsafe operation
- Fast speed of response
- Reduced routine maintenance
- Immune to catalytic poisons
- Long operating life
- Works in inert atmospheres
Applications
The XNX transmitter is a highly versatile and advanced gas detection instrument designed for a wide range of applications. The XNX Universal Gas Transmitter is widely used across various industries, including:
- Oil and gas
- Chemical processing
- Food and beverage
- Pharmaceuticals
- Fire detection and suppression systems
- HVAC systems
- Water and wastewater treatment
- Power generation
- Transportation
Buying Guide for XNX Universal Gas Transmitter
When selecting an XNX Universal Gas Transmitter, it is crucial to consider several key factors to ensure you choose the right configuration for your specific application:
- Identify the specific type of gas or gasses you need to detect. Different sensors are designed for different gasses, ensuring the transmitter is equipped with the appropriate sensor(s) for your gas detection needs.
- Determine the concentration range of the gas(es) you need to detect in your environment.
- Consider the environmental conditions where the transmitter will be installed and operated. Factors such as temperature, humidity, potential exposure to corrosive substances, and explosive atmospheres should be taken into account.
- Assess your budget constraints and select an XNX transmitter configuration that fits within your budget while meeting your gas detection requirements.
- Ensure that the XNX Universal Gas Transmitter and its components comply with relevant safety and industry standards, such as those related to hazardous area classification, to guarantee the safety and reliability of your gas detection system.
- Consider the ease of maintenance and serviceability of the transmitter. A system with self-diagnostic features can reduce maintenance costs and downtime.
By carefully evaluating these factors, you can choose the most suitable XNX Universal Gas Transmitter configuration to meet your specific gas detection requirements and environmental conditions while staying within your budget constraints.
Xnx Transmitter Honeywell Price 2024
Xnx Transmitter Name | Item # | Price |
---|---|---|
Honeywell Analytics XNX Universal Transmitter 4 x 50, HART® over 4-20 mA output, UL/CSA/FM approved, 5 x 3/4 in. NPT entries, painted LM25, configured for Searchline Excel – XNX-UTAI-NNNNN | Item #:XNX-UTAI-NNNNN | $893.00 |
Honeywell Analytics XNX Universal Transmitter, HART® over 4-20 mA output, UL/CSA/FM approved, 5 x 3/4 in. NPT entries, painted LM25, with local HART® interface port, configured for Searchline Excel – XNX-UTAI-NHNNN | Item #: XNX-UTAI-NHNNN | $1,378.00 |
Honeywell Analytics XNX Universal Transmitter, HART® over 4-20 mA output, UL/CSA/FM approved, 5 x 3/4 in. NPT entries, painted LM25, with | Item #: XNX-UTAI-MNNNN | $1,194.00 |
Honeywell Analytics XNX Universal Transmitter 40, Foundation Fieldbus output, UL/CSA/FM approved, 5 x 3/4 in. NPT entries, painted LM25, configured for Searchline Excel – XNX-UTAI-FNNNN | Item #: XNX-UTAI-FNNNN | $1,765.00 |
Honeywell Analytics XNX Universal Transmitter, HART® over 4-20 mA output, UL/CSA/FM approved, 5 x 3/4 in. NPT entries, painted 316 stainless steel, configured for Searchline Excel – XNX-UTSI-NNNNN | Item #: XNX-UTSI-NNNNN | $1,012.00 |
Honeywell Analytics XNX Universal Transmitter, HART® over 4-20 mA output, UL/CSA/FM approved, 5 x 3/4 in. NPT entries, painted 316 stainless steel, with local HART® interface port, configured for Searchline Excel – XNX-UTSI-NHNNN | Item #: XNX-UTSI-NHNNN | $1,277.00 |
Honeywell Analytics XNX Universal Transmitter, ATEX M25 AL FF HRT FOR TOX/O2 SNSR – XNX-AMAE-FHNNN | Item #: XNX-AMAE-FHNNN | $2,534.00 |
Honeywell Analytics XNX Universal Transmitter, ATEX M25 AL FF FOR TOX/O2 SNSR – XNX-AMAE-FNNNN | Item #: XNX-AMAE-FNNNN | $2,233.00 |
Honeywell Analytics XNX Universal Transmitter, ATEX M25 AL MDBS FOR OPT/XL SNSR – XNX-AMAI-MNNNN | Item #: XNX-AMAI-MNNNN | $1,194.00 |
Honeywell Analytics XNX Universal Transmitter, ATEX M25 AL MDBS HRT FOR OPTXL SNSR – XNX-AMAI-MHNNN | Item #: XNX-AMAI-MHNNN | $1,501.00 |
Honeywell Analytics XNX Universal Transmitter, ATEX M25 AL FF HRT FOR OPT/XL SNSR – XNX-AMAI-FHNNN | Item #: XNX-AMAI-FHNNN | $2,066.00 |
Technical Summary Xnx Transmitter Honeywell
Electrical | |||
Input Voltage Range E | EC and mV versions 16 to 32Vdc, IR version 18 to 32 Vdc (24Vdc nominal) | ||
Max Power Consumption | XNX EC (Toxic): 6.2 watts XNX mV (Catalytic or IR cell): 6.5 watts XNX IR with Searchpoint Optima Plus: 9.7 watts XNX IR with Searchline Excel Receiver: 13.2 watts | ||
Construction | |||
Material | Housing: 5-coat marine finish painted aluminium alloy or 316 stainless steel | ||
Weight (Approx.) | Aluminium alloy: 2.8kg (6.2lbs). 316 stainless steel: 5kg (11lbs) | ||
Dimensions | 160mm x 197mm x 114mm (6.1″ x 7.8″ x 4.5″ | ||
Environmental | |||
IP Rating | IP66 in accordance with EN60529:1992. NEMA 4X | ||
Operating Temperature | -40ºC to +65ºC (-40ºF to +149ºF) | ||
Operating Humidity | 0-99%RH (non condensing) | ||
Operating Pressure | 90-110kPa | ||
Storage Conditions | -40ºC to 75ºC (-40ºF to 167ºF), 0-99% non-condensing | ||
Functions Supportedby HART® | |||
Gas readingGas name and units of measurement4-20mA signal levelGeneral/device informationInstallationConfigurationForcing of 4-20mA output | Detailed sensor information including:Optical signal levelDynamic reserve (Searchline Excel only)Raw reading24V supply voltageTemperature | Calibration and configuration statusDetailed fault and warning informationFault and alarm historyZero calibration | |
Communication Options | |||
Relays | Type: 3 form “C” SPCO contacts for alarm and fault indication.Rating: 250 VAC, 5A/24 VDC, 5A (2 Alarm, 1 Fault)A remote reset is provided to silence alarms. (The FOUNDATION Fieldbus, relay, and Modbus options are mutually exclusive.) | ||
Modbus | Modbus/RTU over RS-485 physical layer. Interface isolated; includes switchable 120 Ohm termination resistor.Baud rates: 1200 to 38,400; 19,200 default.(The FOUNDATION Fieldbus, relay, and Modbus options are mutually exclusive.) | ||
FOUNDATION Fieldbus | H1 Physical Layer.31.25 kbit/s Manchester encoded signal.AMIS-49200 Fieldbus MAU (media access unit).SPC4-2 Fieldbus Controller.The FOUNDATION Fieldbus, relay, and Modbus options are mutually exclusive. |
Final Thoughts
The XNX Universal Gas Transmitter by Honeywell Analytics is a highly adaptable and dependable gas detection solution with a wide range of applications. Its modular design, user-friendly interface, and diagnostic capabilities make it a preferred choice for many industries and scenarios where gas detection and safety are paramount.